Measurements
Rock It Sounds R-50
• Dual BA
• US $119.99 [MSRP]
Rock It Sounds R50 measurements
[1. Frequency Response ]
Uncompensated
Diffuse Field Target Compensated
Harman Target Compensated
CSD
[2. Square Wave ]
30 Hz
300 Hz
[3. Minimum Phase ]
[4. Harmonic Distortions ]
94 dB SPL at 500 Hz
[5. Impedance Magnitude ]
Black: Impedance Magnitude
Green: Electrical Phase
[6. Insertion Depth ]
Uncompensated
Black: 5.5 mm
Orange: 1 mm
Away from the reference plane
Diffuse Field Target Compensated
Black: 5.5 mm
Orange: 1 mm
Away from the reference plane
[7. Comparison ]
Diffuse Field Target Compensated
Black: Rock it Sounds R-50
Orange: Etymotic Research ER-4P
Diffuse Field Target Compensated
Black: Rock it Sounds R 50
Orange: Etymotic Research ER4SR
Interesting comparison with the Etymotics. Which one sounds better, in your opinion?
ReplyDeleteOf course etymotic..
DeleteYeah, I prefer ER4XR.
Delete