Measurements


Rock Zircon

• 8 mm dynamic driver
• One-button remote for iOS & Android
• $25.6 USD [MSRP]


Rock Zircon measurements

Check the Measurement Procedures first.

[1. Frequency Response ]
Uncompensated


Diffuse Field Target Compensated


Harman Target Compensated


CSD



[2. Square Wave ]
30 Hz

300 Hz



[3. Minimum Phase ]



[4. Harmonic Distortions ]
94 dB SPL at 500 Hz



[5. Impedance ]
Black: Impedance Magnitude 
Green: Electrical Phase 





4 comments:

  1. The left channel has suspicious behavior, might be defective somehow. Then again, +25 dB to the bass doesn't sound like a proper design either.

    Was the impedance plot taken from the left driver?

    ReplyDelete
    Replies
    1. I usually measure the impedance with both channels and upload it with only right channel. If there are significant differences between each other, I'll stipulate the both channels.

      For example,
      http://clarityfidelity.blogspot.com/2016/04/lz-a2-iem.html

      Delete
  2. The distortion figures are confusing? What is reaching 2% in the 1-2kHz range? If it is THD, then it will sound terrible.